产品详情
  • 产品名称:4230系列连续过程中氢与二氧化碳气体分析仪

  • 产品型号:4230系列连续过程中氢与二氧化碳气体分析仪
  • 产品厂商:其它品牌
  • 产品文档:
你添加了1件商品 查看购物车
简单介绍:
4230系列连续过程中氢与二氧化碳气体分析仪 对于氢气(H2)的连续分析与Active二氧化碳(CO2)的赔偿。推荐放热(dx)上的气氛从一连续分析气体发生器或一炉等工艺气体
详情介绍:
4230系列连续过程中氢与二氧化碳气体分析仪
对于氢气(H2)的连续分析与Active二氧化碳(CO2)的赔偿。推荐放热(dx)上的气氛从一连续分析气体发生器或一炉等工艺气体
4230-N4-H2--CO2

larger image
For continuous analysis of Hydrogen (H2) with active Carbon Dioxide (CO2) compensation. Recommended for continuous analysis of exothermic (DX) atmosphere gases from a generator or a furnace, and other process gases.

Search Items


Request QuoteCompare Items   Results per Page : 
  Results 1 - 11 of 11   1 
 
 

Item #

Enclosure and Mounting Details

Resolution

Output Options

Analyzer Type

Hazardous Area Rating Options

Model 4230N4 Process Analyzer for Hydrogen with Carbon Dioxide Compensation, Wall Mounted NEMA4 (IP65) Enclosure Rating 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer General Purpose, Non-Hazardous
Model 4230N4X Process Analyzer for Hydrogen with Carbon Dioxide Compensation, Wall Mounted Corrosion-resistant NEMA4X (IP65) Enclosure Rating 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer General Purpose, Non-Hazardous
Model 4230N12 Process Analyzer for Hydrogen with Carbon Dioxide Compensation, Wall Mounted NEMA12 (IP52) Enclosure Rating 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer General Purpose, Non-Hazardous
Model 4230PM Process Analyzer for Hydrogen with Carbon Dioxide Compensation, Panel Mounted, Slides Open for Easy Access 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer General Purpose, Non-Hazardous
Model 4230RM Process Analyzer for Hydrogen with Carbon Dioxide Compensation, 19" (483mm) Rack Mounted, on Sliding Rails 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer General Purpose, Non-Hazardous
Model 4230N7MC Process Analyzer for Hydrogen with Carbon Dioxide Compensation, Wall Mounted NEMA7 UL/CSA Explosion-Proof with Non-intrusive Magnetic Calibration, Meets Class 1 Div 1 Group BCD 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 4230PMN7 Process Analyzer for Hydrogen with Carbon Dioxide Compensation, Wall Mounted NEMA7 Sensor Housing with Panel Mounted Control Cabinet (Two Separate Enclosures) 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer Class 1, Div 1, Grp A-D Hazardous Area Rating
Model 4370 Process Analyzer for Hydrogen with Carbon Dioxide Compensation, H2 with CH4 Compensation 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer N/A
Model 4381 Process Analyzer for Hydrogen with Carbon Dioxide Compensation, H2 with CO compensation 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer N/A
Model 42381 Process Analyzer for Hydrogen with Carbon Dioxide Compensation, H2 with CO & CO2 compensation 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer N/A
Model 42387 Process Analyzer for Hydrogen with Carbon Dioxide Compensation, H2, with CO2, CO, & CH4 compensation. 0.1% H2 and CO2 4-20 mA into 500 ohms non-isolated standard
Isolated 4-20 mA, RS232, RS485, MODBUS, Ethernet outputs
H2 Analyzer N/A